18.2m liquid ammonia spherical tank was successfully installed with Non-Intrusive Ultrasonic Level Gauge

Abstract

  1. Date: July 21, 2019
  2. Location: Hancheng, Shaanxi
  3. Customer name: Longmen minghua Company
  4. Storage tank: Spherical tank
  5. Medium: Liquid Ammonia
  6. Diameter: 18.2m
  7. Wall thickness: 50mm
  8. The problem solved: the user had used the external level gauge from other manufacturers before, but the level gauge jumped badly and the measurement was unstable.  After investigation and inquiry from multiple parties, he finally chose the two-wire system of Non-Intrusive Ultrasonic Level Gauge produced by SKE, which has stable operation, accurate measurement and convenient installation and debugging.
Spherical tank-shaanxi

Installation of measuring probe

Installation of measuring probe

Calibration probe installation

Calibration probe installation

Install transmitter

Install transmitter
Install transmitter
Install transmitter

Final debugging

Final debugging
Final debugging
Final debugging
Final debugging
Final debugging
Final debugging