• The installation time: 2017-04-13
  • The installation location: Shan dong province
  • Measuring the dielectric: Propene
  • Tank shape: Horizontal tank
  • Measuring equipment: Non-invasive Ultrasonic Level Gauge

Brief introduction: The Non-invasive Ultrasonic Level Gauge is installed and used in a trichloropropane vertical tank of a certain chemical Industry Co., LTD. The trichloropropane storage tank is made of 7.5 meters cast iron vertical tank, with the installation position of measuring probe at the bottom.

The Non-invasive Ultrasonic Level Gauge is installed and used in a trichloropropane vertical tank of a certain chemical Industry Co., LTD. The trichloropropane storage tank is made of 7.5 meters cast iron vertical tank, with the installation position of measuring probe at the bottom.

Notes for installation of Non-invasive Ultrasonic Level Gauge in trichloropropane vertical tank:
The bottom of the vertical tank shall be installed with a probe of 200mm*200mm*300mm
The orientation of the probe should be perpendicular to the measured level.
There is no obstruction such as pipe directly above the probe.
Keep away from the lower inlet to avoid the influence of the vigorous flow of the inlet on the measurement.
Avoid the upper inlet position, so as to avoid the impact of inlet impact on the measurement of liquid level fluctuation.
Higher than outlet or outlet to avoid long-term deposition of dirt on tank bottom.
If conditions are not met, measures should be taken to ensure periodic removal of contaminants from tank bottom.
The walls of the vessel where the installation dimensions should be no less than 100 Ф circular surface, the surface roughness should reach 1.6, the inclination should be less than 3 °.